50-70 BHP General Boiler Conditions
Fuel: Natural Gas, LPG, & #2 Oil
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less modulating gas burner (Lamtec Controller Inbuilt)
Supplied with :
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less dual fuel burner (Lamtec Controller), modulation on gas, low-high-low on #2 oil.
Supplied with :
70-125 BHP General Boiler Conditions
Fuel: Natural Gas, LPG, & #2 Oil
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less modulating gas burner (Lamtec Controller Inbuilt)
Supplied with :
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less dual fuel burner (Lamtec Controller), modulation on gas, low-high-low on #2 oil.
Supplied with :
150-200 BHP General Boiler Conditions
Fuel: Natural Gas, LPG, & #2 Oil
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less modulating gas burner
Supplied with :
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less dual fuel burner, full modulation on gas & LHL oil
Supplied with :
200 BHP High Altitude
Fuel: Natural Gas, LPG
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less modulating gas burner
Supplied with :
250-300 BHP General Boiler Conditions
Fuel: Natural Gas, LPG
Voltage: 110V, 220V, 460V, or 575V/3/60
Linkage less modulating gas burner
Supplied with :
S-burner is typically used in hot water and steam boilers, but is suitable also in various further applications. The amount and ratio of primary and secondary air can be adjusted. Secondary air is guided through adjustable air vanes, which enables the formation of the desired flame shape and thus matching optimally to the furnace dimensions. Additionally, the adjustability contributes to achieving the required emission levels in different furnace sizes and forms.
By request, S-burner is capable to be provided with single or dual-fuel liquid lance, gas lance and gas ring.
Litex brings a design focus to the form of the burner wind box: the burner shapes optimize air flows in the wind box and the combustion head. Thus advance, achieved through computational fluid dynamics (CFD), has resulted in stable combustion and low NOx emissions. And to reduce NOx emissions still further, it is possible to operate Litex units also with external flue gas recirculation (FGR): a small amount of flue gases means considerable NOx reductions. The burner is small and also extremely light for its burner capacity. With Litex, installation is easy too: for example, the burner refractory has a straight-cylinder design. An ideal solution for many fields of application, Litex burners are most typically used in hot water and steam boilers.
K-burner is the right choice for many different types of industrial processes, for example in hot air generators, hazardous waste and municipal waste incineration plants. The combustion air inlet is located eccentric on one side of the burner guiding the combustion air tangentially to the wind box, which causes a strong swirl and stable flame.
The burner construction is designed for heavy duty operation to guarantee good availability in extreme process conditions. K-burner can be equipped with several lances according to the number of different fuels.
Lance burner presents technology to different demanding industrial purposes, for example as start-up and support burner in fluidized bed boilers. It is essential, that the parts will tolerate the effects of the sand bed. This is achieved in lance burner by optimized cleaning and cooling air flow through the burner. When the burner is stand-by, the critical parts will be retracted automatically. The small diameter of the lance burner allows to minimize burner openings on the boiler walls.